3-phase 400V series | ||||||
---|---|---|---|---|---|---|
Item | Specification | |||||
Type (FVR AS1S-4E) | FVR0.4AS1S-4E | FVR0.75AS1S-4E | FVR1.5AS1S-4E | FVR2.2AS1S-4E | FVR3.7AS1S-4E | |
Applicable motor rating [kW] | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | |
Output | Rated voltage [V] | Equal to Input voltages with the deviation of less than 5% | ||||
Rated current [A]*1 | 1.5(1.8) | 2.5(2.5) | 4.2(4.3) | 5.5(6.3) | 9.0(10.5) | |
Overload capability | 150% of rated output current 1 minute | |||||
Frequency/Fluctuation | Rated frequency : 50/60 Hz Frequency range : 0.1 to 400Hz |
|||||
Input | Voltage/Allowable | 3-phase 380(-15%) to 480 V(+10%) | ||||
Frequency [Hz] | 50Hz or 60Hz (Allowed range : 47 ~ 63Hz) | |||||
Input current [A] | 1.7 | 3.1 | 5.9 | 8.2 | 13 | |
Braking transistor | Built-in | |||||
Enclosure | IP20 (IEC 60529), UL open type (UL50) | |||||
Cooling method | Natural cooling | Fan cooling |
Single-phase 200V series | |||||
---|---|---|---|---|---|
Item | Specification | ||||
Type (FVR AS1S-7E) | FVR0.4AS1S-7E | FVR0.75AS1S-7E | FVR1.5AS1S-7E | FVR2.2AS1S-7E | |
Applicable motor rating [kW] | 0.4 | 0.75 | 1.5 | 2.2 | |
Output | Rated voltage [V] | Equal to Input voltages with the deviation of less than 5% | |||
Rated current [A]*1 | 2.5(3.5) | 4.2(4.2) | 7.5(9.2) | 10(10) | |
Overload capability | 150% of rated output current 1 minute | ||||
Frequency/Fluctuation | Rated frequency : 50/60 Hz Frequency range : 0.01 to 400Hz |
||||
Input | Voltage/Allowable | Single-phase 200V(-10%) to 240 V(+10%) | |||
Frequency [Hz] | 50Hz or 60Hz (-5% to +5%) | ||||
Input current [A] | 5.4 | 9.7 | 16.4 | 24 | |
Braking transistor | Built-in | ||||
Enclosure | IP20 (IEC 60529), UL open type (UL50) | ||||
Cooling method | Fan cooling | ||||
Mass [kg] | 0.6 | 0.6 | 1.0 | 1.1 |